Overview
Basic Info.
Model NO. EM500
Principle of Work Vector Control Transducer
Switch Mode PWM Control
Main Circuit Type Voltage
Voltage of Power Supply Low Voltage Variable-Frequency Drive
Link of Transformation AC-AC Variable-Frequency Drive
Nature of DC Power Voltage Variable-Frequency Drive
Function General VFD
Brand Sinee
Rated Voltage of Power Supply 380V-20%~415V+20%
Driving Mode Vvf;SVC
Input Mode Frequency (Speed) Input, Torque Input
Reference Power Supply 10V/20mA
Terminal Control Power 24V/200mA
Vibration Less Than 0.5g
Protection Level Standard IP20/IP21
Cooling Method Forced Air Cooling
Transport Package Wooding
Trademark SINEE
Origin China
Production Capacity 400000pieces/Year
Product Description
Customized Control High-Tech Variable Frequency Inverters

Three-phase 380~415V 0.75~630kW

The EM500 series inverter is an open-loop vector control inverter. It supports the three-phase AC asynchronous motor; a variety of drive control technologies: improved vector VF control technology (VVF), speed sensorless vector control technology (SVC); speed output and torque output; expansions: I/O expansion cards, and communication bus expansion cards.


The EM500 series high-performance vector inverter has the following features:
1.High torque control accuracy
2.Wide speed range and high control accuracy
3.Low-frequency carrier: VVF/1Hz/150%, SVC/0.25Hz/150%
4.Support I/O expansion
5.Support communication bus expansion: 485 bus, Profibus-DP network, CANopen network;
6.Built-in DC reactor above 11kW to increase the power factor and enhance the product reliability;
7.Support a variety of dedicated functions: constant-pressure water supply, air compressor, torque winding and unwinding, straight wire-drawing machine, etc.

Product Description Product Parameters
Item Specification
Power supply Rated voltage of power supply 380V-20%~415V+20%
Rated voltage and frequency of power supply 50-60Hz ± 5%; voltage unbalance rate: <3%
Output Maximum output voltage The maximum output voltage is the same as the input power voltage.
Rated output current Continuous output of 100% rated current
Maximum overload current G model: 150% rated current: 60s; 180% rated current: 10s; 200% rated current: 2s P model: 120% rated current: 60s; 150% rated current: 10s; 180% rated current: 2s
Basic control Driving mode V/F control (VVF); speed sensorless vector control (SVC)
Input mode Frequency (speed) input, torque input
Start and stop control mode Keyboard, control terminal (two-line control and three-line control), communication
Frequency control range 0.00~600.00Hz/0.0~3000.0Hz
Input frequency resolution Digital input: 0.01Hz/0.1Hz Analog input: 0.1% of maximum frequency
Speed control range 1:50(VVF),1:200(SVC)
Speed control accuracy Rated synchronous speed ± 0.2%
Acceleration and deceleration time 0.01 s to 600.00 s / 0.1 s to 6,000.0 s / 1 s to 60,000 s
Voltage/frequency characteristics Rated output voltage: 20% to 100%, adjustable; fundamental frequency: 1Hz to 600Hz/3000Hz, adjustable
Torque boost Fixed torque boost curve, any V/F curve optional
Starting torque 150%/1Hz(VVF),150%/0.25Hz(SVC)
Torque control accuracy ±8% rated torque (SVC)
Self-adjustment of output voltage When the input voltage changes, the output voltage will basically remain unchanged.
Automatic current limit Output current is automatically limited to avoid frequent overcurrent trips.
DC braking Braking frequency: 0.01 to maximum frequency Braking time: 0~30S Braking current: 0% to 100% of rated current
Signal input source Communication, multi-speed, analog, high-speed pulse, etc.
Input and output Reference power supply 10V/20mA
Terminal control power 24V/200mA
Digital input terminal 7 (standard X1 to X7) + 4 (extension card X8 to X11) digital multi-function inputs: X7 can be used as a high-speed pulse input terminal (F02.06 = 35/38/40); The remaining 10 channels (X1 to X6 and X8 to X11) can only be used as ordinary digital input terminals
Analog input terminal 3 (standard AI1 to AI3) + 1 (extension card AI4) analog inputs: One (AI1) voltage source: 0 to 10V input Two (AI2/AI3): 0 to 10V input voltage or 0 to 20mA input current optional; One (AI4) voltage source: -10V to 10V input
Digital output terminal 2 (standard Y1/Y2) + 1 (extension card Y3) open-collector multi-function outputs and 2 (R1: EA/EB/EC and R2:RA/RB/RC) relay multi-function outputs. Maximum output current of the collector: 50mA; relay contact capacity: 250VAC/3A or 30VDC/1A, with EA-EC and RA-RC normally open and EB-EC and RB-RC normally closed
Analog output terminal Two (M1/M2) 0-10V/ 0-20mA multi-function analog output terminals
Operation panel LED display The LED digital tube displays relevant information about the inverter.
Parameter copying Parameter settings of the inverter can be uploaded and downloaded for fast parameter copying.
Protection Protective Function Short circuit, overcurrent, overvoltage, undervoltage, phase loss, overload, overheat, overspeed, load loss, external fault, etc.
Use conditions Location Indoor, at an altitude of less than 1 km, free of dust, corrosive gases and direct sunlight
Applicable environment -10ºC to +40ºC, 20% to 90%RH (non-condensing)
Vibration Less than 0.5g
Storage environment -25ºC~+65ºC
Installation method Wall-mounted, floor-standing electrical control cabinet, through-wall
Protection level Protection level Standard IP20/IP21 (450kW and above)
Cooling method Cooling method Forced air cooling